ISO 9001 CERTIFIED  ·  CONSULTANT APPROVED  ·  EXPORTING SINCE 2005
HOME/EQUIPMENT/CHEMICAL STORAGE TANKS
FRP chemical storage tank farm with access ladders and platforms
HAND LAY-UP FRP STORAGE TANKS
STORAGE & PROCESS · TANKS

FRP chemical storage & process tanks, 10 m³ to 300 m³

Hand lay-up and spray-up tanks in FRP, PP/FRP, HDPE/FRP, PVDF/FRP, FEP/FRP and PFA/FRP, for acids, alkalis and process liquors. Designed to BS EN 13121 and tested before despatch.

1,000+
Tanks delivered, 10 m³ to 300 m³
300 m³
Largest FRP tank — Ø 6,000 × 8,000 mm
~100
Tanks built each year
BUILT TO BS EN 13121
01 — CONFIGURATIONS

Four ways to build a tank, chosen by size and service.

Construction method follows the duty. Hand lay-up and spray-up for most tanks and complex shapes, thermoplastic and fluoropolymer liners for chemistry, filament winding for large cylindrical storage, and site fabrication when it will not fit on a truck.
TYPE 01
Hand lay-up and spray-up FRP
The default for storage and process tanks, and for conical bottoms, rectangular sections and non-standard shapes.
STORAGE & PROCESS
TYPE 02
Dual-laminate PP, HDPE, PVDF, FEP and PFA/FRP
A thermoplastic or engineering fluoropolymer liner for chemical resistance, FRP for structure.
AGGRESSIVE SERVICE
TYPE 03
Filament-wound FRP
Continuous winding for the highest hoop strength per kilogram, for large cylindrical storage.
CYLINDRICAL STORAGE
TYPE 04
Site-fabricated tanks
Built at your site when the diameter exceeds what can be transported.
100 M³ AND ABOVE
02 — SPECIFICATION

The envelope, in numbers.

The laminate schedule is worked out against the governing code and checked by FEA analysis before any prototyping is done.

PARAMETER
RANGE / CAPABILITY
Capacity
10 m³ to 300 m³ (10,000 – 300,000 L)
Largest executed
Ø 6,000 mm × 8,000 mm shell
Construction
Hand lay-up · spray-up · filament wound · site fabricated
Materials
FRP · PP/FRP · HDPE/FRP · PVC/FRP · PVDF/FRP · FEP/FRP · PFA/FRP
Resin systems
Isophthalic · bisphenol · vinyl ester
Design codes
BS EN 13121
Structural verification
FEA analysis before prototyping
Testing
Hydro test · laminate DT and NDT in house
Design temperature
30 – 120 °C
Annual output
~100 tanks between 10 m³ and 200 m³
Every unit is sized against the actual duty.
03 — APPLICATIONS

What our tanks hold

Acids
Hydrochloric · sulphuric · nitric · phosphoric · hydrofluoric (with liner)
Alkalis and oxidisers
Caustic soda · sodium hypochlorite, with the appropriate resin
Process liquors
Plating and pickling solutions · brine · effluent · scrubber liquor
Industries
Chemicals · pharma · metals · water treatment · paints
04 — HOW WE SIZE IT

What decides the laminate.

Chemistry and temperature. These choose the resin and corrosion barrier, and whether a thermoplastic or engineering fluoropolymer liner is needed.
Specific gravity and head. These set the hoop load and the structural laminate thickness.
Installation conditions. Indoor or outdoor, wind and seismic loads, and the foundation.
Connections and access. Nozzle loads, manways, ladders, platforms and level instruments.
TO QUOTE, SEND US
Chemical stored and concentration Operating temperature Atmospherically vented, under pressure or subject to vacuum Capacity or diameter × height Indoor or outdoor installation Nozzle schedule, if available
Start an enquiry
05 — CONSTRUCTION

What goes into every tank

01
Corrosion barrier
A resin-rich inner layer with surfacing veil, or a thermoplastic or engineering fluoropolymer liner — the part that actually meets the chemical.
02
Structural laminate
Hand lay-up, spray-up or filament-wound glass to carry the hydrostatic and external loads.
03
UV-resistant exterior
An external topcoat for outdoor installations.
04
Nozzles, manways and lugs
Reinforced connections, lifting lugs and hold-down lugs sized to the code.
05
Access
Ladders, platforms and handrails where required.
REFERENCE INSTALLATION
3 + 3
80 M³ AND 125 M³ STORAGE TANKS
Pigments manufacturer, Maharashtra
Three 80 m³ and three 125 m³ FRP storage tanks, supplied as one package.
06 — IN SERVICE

Units we have built and commissioned

All projects →
frp storage tank farm
FRP STORAGE TANK FARM
frp tank under fabrication at site
FRP TANK · FABRICATION AT SITE
pph process tanks on a steel support frame
PPH PROCESS TANKS
process vessel
PROCESS VESSEL
07 — QUESTIONS

What engineers ask us first

These answers are also written for search. Each question is a query buyers type into Google, which is why the FAQ block sits on every equipment page.

Why FRP rather than MSRL or stainless steel?+
FRP resists a wide range of acids and chlorides without a rubber lining to maintain, weighs less, and usually costs less than the alloy that would do the same job. It also avoids the weak point of lined steel: a lining and a steel shell expand at different rates with temperature, which is how linings crack and disbond. FRP has no separate lining to fail.
Hand lay-up or filament wound?+
Hand lay-up and spray-up suit most storage and process tanks, and handle conical bottoms, rectangular shapes and complex fittings. Filament winding gives the highest hoop strength for large cylindrical storage.
When do I need a dual-laminate tank?+
When the chemical would attack even a premium resin — hydrofluoric acid, some oxidisers, high-purity service. A PP, HDPE, PVDF, FEP or PFA liner handles the chemistry and FRP carries the load.
What is the largest tank you can build?+
300 m³ executed, at Ø 6,000 × 8,000 mm. Beyond transportable diameters we fabricate at site.
How are tanks tested?+
Hydrostatic testing before despatch, with destructive and non-destructive laminate testing in our own facility.
ENQUIRY

Pick the equipment. We will send you the data sheet.

Choose the equipment you need. We will take three details, then send you the enquiry data sheet for that product — the one our engineers use to size and quote.

+91 22 4970 9140·WhatsApp an engineer
Already know what you need? Download data sheets directly
RELATED EQUIPMENT
Bhavi Plast
Bhavi Plast

FRP and dual-laminate process equipment, engineered, built, installed and maintained under one contract. Established 1977.

EQUIPMENT
COMPANY
APPLICATIONS
HCl fume scrubbing
Cl₂ and NH₃ scrubbing
H₂SO₄ mist removal
Flue gas desulphurisation
Pickling line exhaust
Solar PV and semiconductor exhaust
CONTACT
603 Dev Corpora, Cadbury Junction,
Khopat, Thane (W) 400 601
Maharashtra, India

Plant — Mankoli, Bhiwandi
+91 22 4970 9140
contact@bhaviplast.com
© 2026 BHAVI PLAST PRIVATE LIMITED
PRIVACY · TERMS · HSE POLICY · SITEMAP
WhatsApp an engineer +91 22 4970 9140